This application is made for power system professionals who are involved in design, configuration, purchasing or operation of telecom power systems. It indicates potential savings that can be realized in two situations:a) if replacing old rectifier equipment with Eltek’s latest high efficiency equipment in ordinary telecom power systemsb) if upgrading off/poor grid sites to optimal smart energy management solutions, with or without use of renewable energyThe application calculates energy savings, energy cost savings and CO2 emission savings; and it visualizes total opex savings over a 10 year period. It also provides the opportunity to send a summary of calculations to an e-mail address.Replacing old rectifier equipmentThe user is asked to input information about his current system:• No. of sites• Average load • kWh cost• EfficiencyThe application calculates• Energy savings (MWh/yr)• Reduced electricity cost ($/yr)• Reduced CO2 reduction (tons/yr)Visualization:• 10 year incremental opex development with old and replaced equipmentUpgrading off/poor grid sites to optimal smart energy management solutionsSituation A: optimization of hybrid installations that include power input from diesel generators and solar panels and use of Eltek’s HE solar charger.The user is asked to input information about his current system:• No. of sites• Average load• Diesel cost• Solar energy contribution (%)Situation B: optimization and cyclic operation of installations powered only by diesel generatorsThe user is asked to input information about his current system:• No. of sites• Average load• Diesel costFor both situations A and B, the application calculates:• Reduced fuel consumption (l/yr)• Reduced fuel cost ($/yr)• Reduced maintenance cost ($/yr)The application also visualizes incremental opex development over 10 years for current and optimized solutions.The calculations rely on the following assumptions:• Generator maintenance: service required for each 250 hrs operation – at cost usd 250.• Battery lifetime: 3 years (avg. battery temperature 25oc)Generator operation: continuous 24/7 operation, at 20% of rated capacity average load input by user: 80% of peak loadNOTE: Disclaimer: The results of the application’s calculations are indicative only and may differ from actual savings, depending on a number of local and specific conditions. Eltek assumes no responsibility for decisions made solely on the calculations of this application.

【免費工具App】HE Calc-APP點子

【免費工具App】HE Calc-APP點子

【免費工具App】HE Calc-APP點子

【免費工具App】HE Calc-APP點子

免費玩HE Calc APP玩免費

免費玩HE Calc App

HE Calc APP LOGO

HE Calc LOGO-APP點子

HE Calc APP QRCode

HE Calc QRCode-APP點子
熱門國家系統支援版本費用APP評分上架日期更新日期
未知iOS
App Store
1.2.1
App下載
免費
2012-07-192015-06-03
シェア記事: